{"id":829,"date":"2026-07-16T12:06:50","date_gmt":"2026-07-16T12:06:50","guid":{"rendered":"https:\/\/autosmarts.co\/en\/library\/ev-charging-station-safety-checklist\/"},"modified":"2026-10-14T15:31:33","modified_gmt":"2026-10-14T15:31:33","slug":"ev-charging-station-safety-checklist","status":"publish","type":"libraries","link":"https:\/\/autosmarts.co\/en\/library\/ev-charging-station-safety-checklist\/","title":{"rendered":"EV Charging Station Safety Checklist"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">What this checklist covers<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The EV Charging Station Safety Checklist is a 15-point scorecard for installation approval, earthing, emergency stop, cable management, signage, access control, fire safety, and inspection schedule. Each criterion is scored from 1 to 5 on what the auditor sees on the day, and every gap goes into an action plan with an owner and a close date.<\/p>\n\n\n\n<p class=\"as-chktip wp-block-paragraph\"><strong>AutoSmart tip:<\/strong> EV charging station safety is a continuous operational responsibility, not a one-time installation check. The most common safety failures occur in use \u2014 damaged cables left in service, emergency stops that have never been tested, and charging bays that accumulate slip and trip hazards. Conduct a functional test of each emergency stop on a quarterly basis, and replace any cable showing visible damage the same day.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The checks<\/h2>\n\n\n\n<div class=\"wp-block-group as-checks is-layout-flow wp-block-group-is-layout-flow\"><p class=\"as-checks__note\"><span>Tap Yes, No or Maybe to try it: your answers stay in this page and clear when you refresh. For a detailed walkthrough, <a href=\"#get-pdf\">download our PDF<\/a> or <a href=\"https:\/\/autosmarts.co\/en\/book-a-demo\/\" data-as-track=\"demo\">book a demo<\/a>.<\/span><\/p>\n<div class=\"wp-block-group as-checksec is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Installation approval and earthing<\/h3><p class=\"as-checksec__meta\">4 checks<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">01<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is the EV charging station installation approved by a qualified electrical inspector, with a completion certificate confirming compliance with local wiring regulations on file?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">02<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is the earthing and protective bonding of the charging installation confirmed as correct in the installation certificate, with no unprotected earth fault risk identified?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">03<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is the supply capacity serving the charging installation confirmed as adequate for the total connected load, with diversity factors applied to prevent supply overload under simultaneous charging?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">04<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is the charging installation compliant with the relevant local or national standard for EV charging equipment (IEC 61851, local building code, or equivalent), confirmed in the installation documentation?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group as-checksec is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Emergency stop and cable management<\/h3><p class=\"as-checksec__meta\">4 checks<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">05<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is an emergency stop device (circuit breaker, isolation switch, or emergency disconnect) clearly labelled, easily accessible, and functional for each charging point?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">06<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Are charging cables managed to prevent trip hazards \u2014 with cable management clips, retractable reels, or designated cable routes \u2014 so that in-use cables do not cross pedestrian or vehicle paths?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">07<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Are cables and connectors inspected for damage before each use, with a clear mechanism for users to report or flag a damaged cable without needing to contact a member of staff?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">08<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is a cable replacement process in place that takes a damaged charging cable out of service the same day it is identified, not left in use pending a maintenance visit?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group as-checksec is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Signage and access control<\/h3><p class=\"as-checksec__meta\">3 checks<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">09<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is each charging point clearly identified with its charger type, connector standard, maximum power output, and any usage restrictions \u2014 visible before the user approaches the connector?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">10<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is access to the charging area managed appropriately \u2014 with no uncontrolled vehicle overstay, pedestrian access to live cable areas, or use by non-authorised vehicles during controlled hours?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">11<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is an out-of-service sign or equivalent fault indicator used when a charging point is non- functional, preventing customers from attempting to use a faulty unit?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group as-checksec is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Fire safety and inspection schedule<\/h3><p class=\"as-checksec__meta\">4 checks<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">12<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is appropriate fire suppression equipment available at or near the charging installation, suitable for electrical fires and the battery chemistry likely to be involved in an EV charging incident?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">13<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is a periodic inspection schedule in place for the EV charging installation, covering electrical integrity, connector wear, earth fault protection, and cable condition at defined intervals?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">14<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Are inspection records maintained for the charging installation, with findings and any remedial actions documented and tracked to completion?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n\n\n\n<li class=\"as-check\"><span class=\"as-check__no\" aria-hidden=\"true\">15<\/span><span class=\"as-check__body\"><span class=\"as-check__text\">Is the local fire service aware of the presence and capacity of EV charging infrastructure on the premises, as part of the fire risk assessment for the site?<\/span><span class=\"as-check__answer\" role=\"group\" aria-label=\"Your answer\" hidden><button type=\"button\" data-answer=\"yes\" aria-pressed=\"false\">Yes<\/button><button type=\"button\" data-answer=\"no\" aria-pressed=\"false\">No<\/button><button type=\"button\" data-answer=\"maybe\" aria-pressed=\"false\">Maybe<\/button><\/span><\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Covers installation approval, earthing, emergency stop, cable management, signage, access control, fire safety, and inspection schedule.<\/p>\n","protected":false},"template":"","meta":{"footnotes":"","_as_roles":"","_as_frequency":"","_as_standard":"","_as_source":"","_as_pdf":1060,"_as_solution":556,"_as_guide":0,"_as_case_study":0,"_as_lib_featured":false},"industry_tag":[3],"checklist_topic":[22],"checklist_market":[],"class_list":["post-829","libraries","type-libraries","status-publish","hentry","checklist_topic-ev-readiness"],"_links":{"self":[{"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/libraries\/829","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/libraries"}],"about":[{"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/types\/libraries"}],"version-history":[{"count":3,"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/libraries\/829\/revisions"}],"predecessor-version":[{"id":1306,"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/libraries\/829\/revisions\/1306"}],"wp:attachment":[{"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/media?parent=829"}],"wp:term":[{"taxonomy":"industry_tag","embeddable":true,"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/industry_tag?post=829"},{"taxonomy":"checklist_topic","embeddable":true,"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/checklist_topic?post=829"},{"taxonomy":"checklist_market","embeddable":true,"href":"https:\/\/autosmarts.co\/en\/wp-json\/wp\/v2\/checklist_market?post=829"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}