Saudi ArabiaFire safety

Saudi Civil Defense Compliance Guidebook for Automotive Companies

Fire safety for Saudi showrooms, workshops, paint shops and parts stores: what Civil Defense checks before it renews your Salamah certificate.

Naseef UmarCEO & Founder, AutoSmart Published
  • Edition 1 · 2026
  • 9 standards · 19 checkpoints · 14-page PDF
  • SAR 30,000 and/or 6 months in prison for violating the Civil Defense Law
  • No Salamah means no municipal (Balady) licence renewal
  • SAR 500K per violation proposed in the draft amendment (Dec 2024)

At a glance

Region
Saudi Arabia
Topic
Fire safety
Law
Civil Defense Law
Regulator
Civil Defense
Scope
9 standards · 19 checkpoints
Format
14-page PDF, free
Edition
Edition 1 · 2026
Official texts

Why we wrote this. Written for dealerships and workshops in Saudi Arabia, from the laws published by the Bureau of Experts and linked on this page, and from what automotive networks there ask their auditors to check. It is a summary for audit teams, not legal advice: check the official text before acting.

What this guidebook covers

Few retail sites hold as much fire load as a car dealership: fuelled vehicles, a paint shop, tyres, batteries and welding, with customers walking through. Civil Defense checks the site before it renews the Salamah certificate, and without a valid certificate the Balady municipal licence can't be renewed.

The guidebook sets out 9 Civil Defense standards and 19 checkpoints, from the certificate and fire alarms to sprinklers, exits, flammable liquids and the safety officer, with what good looks like, real enforcement cases and an ideal fix time for each.

The 9 Civil Defense standards

Open a standard to see the law behind it, what is checked, what it can cost and the evidence. Ideal fix times are counted from audit submission.

SAF-001Valid Civil Defense Salamah certificate72 hours
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · Salamah safety certificate required for commercial and industrial facilities · Penalty: Art. 30
What we check
The branch holds a valid, unexpired Salamah safety certificate, and the activities and premises it lists match what the site actually does today.
What it can cost
An expired or mismatched certificate can block the municipal licence. Operating without one risks SAR 30,000 and up to 6 months in prison.
Evidence
Photo of certificate + activity comparison
SAF-002Fire alarm system operationalImmediate
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · Saudi Fire Code SBC 801 (fire detection and alarm systems; inspection, testing and maintenance) · Penalty: Art. 30
What we check
The fire alarm panel shows normal status with no faults or disabled zones, and every detector and manual call point is in place, uncovered and reachable.
What it can cost
If a fire breaks out in a disabled zone, the law allows up to 6 months in prison, and without Salamah the whole site can lose its licence.
Evidence
Photo of panel status + call points + latest maintenance report
SAF-003Fire protection maintenance contract and records7 days
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · SBC 801 (inspection, testing and maintenance of fire protection systems) · Salamah renewal requirements · Penalty: Art. 30
What we check
Fire protection systems are maintained under a valid contract with a Civil Defense-accredited safety contractor, and inspection, testing and maintenance records are current.
What it can cost
An extinguisher that fails in a real fire turns a SAR 30,000 violation into a disaster, and a lapsed contract can stop your Salamah renewal.
Evidence
Contract copy + contractor accreditation + reports
SAF-004Sprinkler system conditionImmediate
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · SBC 801 (automatic sprinkler systems – maintenance) · Penalty: Art. 30
What we check
Sprinkler control valves are open and secured, and sprinkler heads are free of stacked goods, paint and covers.
What it can cost
A closed sprinkler valve in a tyre store is how a small fire becomes a total loss. The law allows SAR 30,000 and 6 months in prison; the draft raises it to SAR 500,000.
Evidence
Photos of valves + storage clearance
SAF-005Emergency lighting and illuminated exit signs24 hours
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · SBC 801 (means of egress illumination and exit signs) · Penalty: Art. 30
What we check
Emergency lights come on when power fails, and illuminated exit and direction signs are lit and visible along every escape route.
What it can cost
If people can't find the exit in a fire, the fine is the least of it. The law allows up to 6 months in prison for safety violations.
Evidence
Test record + photos of signs
SAF-006Evacuation plan and fire drills30 days
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · SBC 801 Ch. 4 (emergency planning and preparedness, evacuation drills) · Penalty: Art. 30
What we check
An approved evacuation plan is displayed at key points, drills are held and recorded at the required frequency, and staff know their fire-emergency roles.
What it can cost
If a fire injures staff or customers and no drill was ever held, the site manager faces questions that can end in prison.
Evidence
Photos of plans + drill log + staff answers
SAF-007Flammable liquids storageImmediate
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · SBC 801 (flammable and combustible liquids) · Penalty: Art. 30
What we check
Fuel, paints, thinners, solvents and alcohol are kept in approved safety cabinets or a designated store, away from ignition sources and electrical panels.
What it can cost
A thinner fire next to a panel spreads in seconds, through a building full of cars. The law allows SAR 30,000 and 6 months in prison; the loss is far bigger.
Evidence
Photos of cabinets + clear zones around panels
SAF-008LPG cylinder installation safetyImmediate
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · SBC 801 (LP-gas) · Penalty: Art. 30
What we check
LPG cylinders are in a ventilated, secured area outside occupied spaces, and hoses, regulators and connections are in good condition with no leaks.
What it can cost
A gas explosion in a workshop is the kind of event the draft law's closure and 1-year prison provisions are written for. Today: SAR 30,000 and 6 months.
Evidence
Photos of cylinder area + hose condition
SAF-009Designated safety officer7 days
The law
Civil Defense Law (Royal Decree M/10 of 10/5/1406H) · General Directorate of Civil Defense (Ministry of Interior) · Civil Defense safety requirements for facilities · Penalty: Art. 30
What we check
A safety officer or responsible person is formally designated for fire safety at the site, and their name and contact details are available on site.
What it can cost
When a fire investigation asks who was responsible and the answer is nobody, the site manager is responsible, with prison on the table.
Evidence
Appointment letter + photo of notice

How to run a Civil Defense fire safety audit in Saudi Arabia, step by step

  1. Confirm what applies. List every building on the site (showroom, workshop, paint shop, parts store) and check the Salamah certificate covers each one.
  2. Walk the site, standard by standard. Score each of the 19 checkpoints Pass, Fail or N/A. N/A only where the standard rules it out, with the reason recorded. Test the alarm panel, open the sprinkler valves' records and walk every escape route.
  3. Capture the evidence. A pass counts only with proof captured at the time of the audit: the certificate, maintenance contract and service records, drill logs and photos of exits, valves and storage.
  4. Give every fail an owner and a fix time. Record what you saw and who owns the fix. Each standard carries an ideal fix time, from immediate to 30 days, counted from audit submission (see the table above).
  5. Fix it, then prove it. The site fixes the cause and uploads proof of closure; the auditor checks the proof before closing the finding.
  6. Re-check at the next audit. Confirm closed findings stay closed, and look for the same fail at your other sites so one gap doesn't repeat across the network.

Who this guidebook is for

  • Dealer principals
  • Facility managers
  • HSE officers
  • Auditors

A reference document, not legal advice. Fines and rules change: check the current text with the regulator or your legal adviser before acting.

Free download

Get the full Saudi Civil Defense Compliance Guidebook for Automotive Companies

14-page PDF, one page per standard. Free: enter your email and it downloads.

  • Every standardThe rule and the costWhich law and regulator, the maximum penalty and what else can happen.
  • Every standardRight way, wrong wayIllustrated pass and fail examples, so front-line staff see what good looks like.
  • Every standardHow to audit itThe checkpoints, the evidence to capture and the ideal time to fix a gap.

Put it into practice

Checklists for this guidebook

Further reading

Another version

Want a different version of this guidebook?

Tell us what you need and we’ll get back to you:

  • Another language, such as Arabic, Spanish or Polish
  • The same guidebook for another country
  • A guidebook on a topic we don't cover yet

Put it into practice

Run your audit programme in AutoSmart

See how every step, from checklist to closed action, works with your own standards.

  • Unlimited users and checklists
  • Works offline
AutoSmart Audit on a laptop, a tablet and a phone